Technical data oil heaters oil heating devices oil heater fans IDS

Show all x IDS 9500
IDS 9500

Technical data Equipment, features and...

Price on request

Technical data
General information
Article number 1.430.000.361
Functional principle
Oil
Method of heating indirect
Air flow rate
Level Max. [m³/h] 12,800
Air pressure
Level Max. [Pa] 250
Fan
axial
Nominal heat input
Level Max. [kW] 225
Nominal heat output
Level Max. [kW] 225
Level Max. [kcal] 193,500
Temperature increase
Level Max. [°C] 50
Electrical values
Mains connection 220 - 240 V, 50 Hz
Current consumption [A] 12.6
Power input [kW] 2.8
Heating capacity [kW] 225
Electric connection
Connection plug CEE 7/7
Operation
Connection for external thermostat
Fuel feed
Fuel feed Riello
Fuel filter
Available
Oil consumption
Level Max. [l/h] 21.44
Hose connection
Diameter | Hose connection [mm] 700
Chimney connection
Available
Diameter | Chimney connection [mm] 200
Sound values
Level Max. - Distance 1 m [dB(A)] 76
Dimensions
Length (packaging excluded) [mm] 2,200
Width (packaging excluded) [mm] 985
Height (packaging excluded) [mm] 1,620
Weight
(packaging excluded) [kg] 380
Equipment, features and functions
Mobility
Wheels
Crane lugs
Housing design
Steel
Safety feature
IP55

 standard equipment

 optionally available

 not available